Zhejiang Type Overhead Line Fault Indicator With LED

Quick Details Model Number: CBDL-JDG Brand Name: Chaobo Joint Type: Pressure Spring Type Application: Overhead 6-35KV High Voltage Cable IP Code: IP65 Place of Origin: Zhejiang, China (Mainland) Lead time for sample: Within 5 days ■ Function and Benefit ◆Indicate the fault line and fault point...

Products Specifications:

Quick Details

Model Number: CBDL-JDG 
Brand Name: Chaobo  
Joint Type: Pressure Spring Type  
Application: Overhead 6-35KV High Voltage Cable
IP Code: IP65  
Place of Origin: Zhejiang, China (Mainland)
Lead time for sample: Within 5 days

 

Function and Benefit

1. High-performance lithium battery with a service life of more than 8 years.

2. A circuit board composed of imported components such as a dedicated chip and a single chip microcomputer.

3. Housing made of aviation and nano materials.

4. It is nickel-plated and has strong magnetic permeability. Card line structure that can be installed electrically.

5. It adopts red fluorescent paint, which is strong in vision and can be clearly indicated under nighttime illumination. And long-term display of the rotating body without fading under outdoor ultraviolet radiation.


 Technical Parameters
◆Applicable voltage grade: U≥6-35KV
◆Applicable wire current: I≤1200A
◆Applicable wire diameter: 16mm sq≤D≤240mm sq
◆Action response time: 0.06s≤t≤3s
◆Reset time: 6,12,24,48H (Selectable, Default 24H)
◆Ambient temperature: -35℃≤T≤+70℃
◆Operation times: ≥5000Times
◆Static power loss: ≤10μW
◆Protection class: IP65


 Action principle
Short circuit detection principle: According to the phenomenon of short circuit,the current break when  short circuit happen, the action on the basis of the protection movement power outages.
Used to judge the short circuit fault indicator diagram
图片1.png  
As line 2# B phase 2,5,8 indicator and line 2# C phase 3,6,9 indicator turn red, but the 11,12 indicator still show white, that judged the point D happen short circuit
Used to judge the grounding fault indicator diagram:
图片2.png  
As line 2# C phase 3,6,9 indicator turn red,but the 12 indicator still show white, that judged the point D happen grounding fault.

 

Products Type:


Test Report: